BLOGS

Respiratory Protection Program Template for BC Employers

Based on the WorkSafeBC OHS Regulation, Part 8 (Respirators).

A fill-in-the-blanks respiratory protection program for BC workplaces.

Why You Need One

Section 8.5 of the WorkSafeBC OHS Regulation requires a program when workers wear respirators against air contaminants. It must include written procedures for selecting, using, inspecting, cleaning, maintaining and storing them, and section 8.6 requires a yearly review.

How to use it: copy the text into a document, fill in the [square brackets] and delete what doesn't apply. It's a starting point, not legal advice; check Part 8 of the current Regulation and CSA Z94.4.

1. Purpose and Scope

[Company name] uses respirators to protect workers from airborne hazards where other controls do not reduce exposure enough. This program covers all workers at [site name(s) / address(es)] who wear a respirator, including those who choose to wear one when it is not required (optional use, section 8.43).

2. Responsibilities

  • Program administrator: [Name, job title]. Responsible for running and reviewing this program.
  • Supervisors: make sure workers wear the right respirator, do seal checks and keep equipment in good condition.
  • Workers: wear only the respirator they were fit tested on, do a seal check every time, report damage and attend training.

3. Hazard Assessment

  • Airborne hazards: [e.g. silica dust, wood dust, welding fume, solvent vapour, wildfire smoke, infectious aerosols].
  • Tasks and areas where respirators are required: [list].
  • Assessment completed on [date] by [person]. Air sampling results, if any: [reference].
  • Other controls in place first: [e.g. wet cutting, local exhaust ventilation, enclosures].

4. Respirator Selection

Task or areaRespirator typeFilter or cartridge
[Task][e.g. N95 / half-face / full-face / PAPR][e.g. P100, organic vapour]

If the table does not display in your document, list each task with its respirator and filter type.

5. Fit Testing (Section 8.40)

  • Every worker who wears a tight-fitting respirator is fit tested before first use and at least once a year after that, per WorkSafeBC requirements.
  • Workers are retested when they change to a different make, model or size. They are also retested when a change in their face could affect the fit, such as significant weight change or dental work.
  • Fit tests follow CSA Z94.4, with qualitative testing for N95 and half-face respirators and quantitative testing for full-face respirators. Our provider: [company name].
  • Workers must be clean-shaven where the respirator seals. Workers who cannot be clean-shaven for religious or medical reasons are offered [e.g. a loose-fitting PAPR].

6. Seal Checks (Section 8.41)

Workers do a positive and negative pressure seal check every time they put on a tight-fitting respirator. A respirator that does not pass a seal check is not used in the hazard area.

7. Training

Workers are trained when they start and at least [once a year], and training is recorded with the date, topic and attendees. It covers the hazards, how to put on, seal check and remove the respirator, its limits, and how to inspect, clean and store it.

8. Inspection, Cleaning, Storage and Cartridge Changes

  • Reusable respirators are inspected before each use and cleaned after use following the manufacturer's instructions.
  • Respirators are stored in a clean, sealed bag or container at: [location].
  • Particulate filters are replaced when damaged, dirty or breathing becomes harder.
  • Gas and vapour cartridges are changed on this schedule: [schedule, e.g. end of each shift or as per manufacturer's service life estimate].

9. Medical Assessment (Section 8.42)

Workers with concerns about wearing a respirator, such as breathing or heart conditions, report them to [name or role]. They are referred for a medical opinion where needed.

10. Records (Section 8.44)

We keep the hazard assessment, fit test results, training records and cartridge change records at: [location or system].

11. Annual Review (Section 8.6)

This program is reviewed every year by [name or role], with the joint health and safety committee or worker health and safety representative. Last reviewed: [date]; next review due: [date].

Need Help with Any Part of This?

We bring on-site respirator fit testing to your workplace, qualitative and quantitative, to CSA Z94.4, with results in your client portal. To fit test in-house, see our fit tester training.